NSN: 5925-01-242-2689

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Boss Height

    0.219 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    3 unthreaded hole and 6 threaded hole and 3 slot

  • Manual Actuator Type And Quantity

    3 toggle

  • Unpackaged Unit Weight

    2.000 pounds

  • Body Width

    3.108 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Body Length

    5.800 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    3.547 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.781 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Mounting Slot Width

    0.178 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    3.234 inches nominal

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...