NSN: 5925-01-247-9901

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    vibration resistant and corrosion resistant and humidity resistant and shock resistant and sand resistant and dustproof and fungus resistant

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    1.187 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Manual Actuator Type And Quantity

    1 push button

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Width

    0.743 inches nominal

  • Body Height

    2.125 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Body Width

    2.250 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.182 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Unpackaged Unit Weight

    8.000 ounces

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.743 inches nominal

  • Terminal Type And Quantity

    6 tab w/screw

  • Body Length

    2.203 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac all locations

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...