Technical Characteristics

  • Trip Release Method

    thermal-magnetic all locations

  • Body Width

    2.240 inches minimum and 2.510 inches maximum

  • Ultimate Trip Time Per Pole In Seconds

    10.000 nominal all locations

  • Trip Release Ambient Temp Rating

    77.0 deg fahrenheit nominal all locations

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Mounting Facility Type And Quantity

    6 threaded stud

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Case Material

    plastic

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Special Features

    function: circuit breaker, magnetic, 40 amp; reference data: cb-4401, instruction book arsr-1d/e/f, vol 5, sec 10, pg 10-759; cb-4401, instruction book arsr-2, vol 5, sec 10, pg 10-563

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Terminal Type And Quantity

    9 tab, solder lug or 6 threaded stud

  • End Item Identification

    air route surveillance radar 1, fa7171 amplitron power supply cabinet; arsr-2, fa7121 amplitron power supply cabinet

  • Body Style

    multipole-multiple actuator type

  • Fragility Factor

    moderately rugged

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...