NSN: 5925-01-251-5016
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Length
1.937 inches nominal
-
Mounting Facility Type And Quantity
6 threaded stud
-
Manual Actuator Type And Quantity
3 toggle
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Terminal Type And Quantity
6 threaded stud
-
Trip Release Characteristic
instantaneous all locations
-
Pole Quantity
3
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Surface To Terminal End Distance
2.469 inches nominal
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
End Item Identification
2 generation vortac (2gvortac)
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Boss Height
0.187 inches nominal
-
Circuit Protection Type
overvoltage all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.781 inches nominal
-
Nominal Thread Size
0.138 inches
-
Body Width
2.250 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Body Length
2.500 inches nominal
-
Special Features
reference data: 1cb1, fa-9996, ti-6820.2, vortac, vor/dme, vor eq., vol 8, sec 8, pg8-68
-
Trip Release Duty Cycle
continuous all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Ultimate Trip Time Per Pole In Seconds
50.000 minimum all locations and 700.000 maximum all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.781 inches nominal