NSN: 5925-01-254-6102

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    3.015 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Boss Height

    0.150 inches nominal

  • Arc Quenching Method

    air

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Unpackaged Unit Weight

    0.760 pounds

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    8 threaded stud

  • Body Length

    2.490 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Pole Quantity

    4

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    4 toggle

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    50.0 all locations or 60.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...