NSN: 5925-01-257-4310

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Thread Series Designator

    unf

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 unthreaded hole

  • Body Width

    4.500 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Center To Center Distance Between Terminals Parallel To Length

    2.797 inches minimum and 2.827 inches maximum

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 dc all locations

  • Body Length

    7.125 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Main Contact Tripping Mechanism Type

    trip free

  • Boss Height

    0.218 inches nominal

  • Unpackaged Unit Weight

    3.300 pounds

  • Manual Actuator Type And Quantity

    2 toggle

  • Body Height

    2.968 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 10.800 maximum at 200 pct all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    125.0 amperes dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Terminal Type And Quantity

    4 quick disconnect, male

  • External Actuator Linkage Arrangement

    one and two linked

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.638 inches minimum and 4.668 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.031 inches nominal

  • Case Material

    plastic

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...