NSN: 5925-01-257-4313
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
8c multipole-multiple actuator type
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Boss Height
0.150 inches nominal
-
Mounting Surface To Terminal End Distance
1.850 inches nominal
-
Body Length
2.490 inches nominal
-
Body Width
2.250 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Fragility Factor
moderately rugged
-
Pole Quantity
3
-
Mounting Facility Type And Quantity
6 threaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 50.0 dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac and 1000.0 dc all locations
-
Circuit Protection Type
overcurrent all locations
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
115.0 ac nominal third location
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
air
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac and 35.0 amperes dc all locations
-
Trip Release Method
magnetic all locations
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip second location
-
Internal Trip Release Configuration
series trip w/auxiliary load terminal and remote trip feature third location
-
Nominal Thread Size
0.138 inches
-
Trip Release Duty Cycle
continuous third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.160 minimum at 200 pct and 1.600 maximum at 200 pct all locations
-
Special Features
2 auxilliary trip coil terminals located at pole 3 only
-
Frequency In Hertz
50.0 or 60.0
-
Thread Series Designator
unc
-
Terminal Type And Quantity
8 threaded stud
-
Manual Actuator Type And Quantity
3 toggle
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip first location
-
Inclosure Protection Type For Which Designed
dustproof