NSN: 5925-01-258-0489
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency In Hertz
60.0
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.240 minimum at 200 pct and 0.800 maximum at 200 pct all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Reset Method
manual
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 2000.0 dc all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 50.0 dc all locations
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac and 20.0 amperes dc third location
-
Mounting Facility Type And Quantity
4 threaded hole
-
Boss Height
0.140 inches minimum and 0.160 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.930 inches minimum and 1.950 inches maximum
-
Body Width
2.230 inches minimum and 2.270 inches maximum
-
Terminal Type And Quantity
6 threaded stud
-
Thread Series Designator
unc
-
Special Features
third pole includes a 115 vac auxilliary trip coil
-
Inclosure Protection Type For Which Designed
general purpose
-
Nominal Thread Size
0.138 inches
-
Internal Trip Release Configuration
series trip all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Actuator Position Designation
at each pole
-
Actuator Function
trip-reset
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Trip Release Characteristic
time delay all locations
-
Trip Release Method
magnetic all locations
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac and 20.0 amperes dc second location
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac and 1.0 amperes dc first location
-
Thread Quantity Per Inch
32
-
Storage Type
general purpose warehouse
-
Arc Quenching Method
magnetic blowout
-
Pole Quantity
3
-
Mounting Surface To Terminal End Distance
2.444 inches minimum and 2.506 inches maximum
-
Fragility Factor
moderately rugged
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.657 inches minimum and 2.677 inches maximum
-
Case Material
plastic
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Body Style
8c multipole-multiple actuator type
-
Thread Pitch Diameters
+0.1177/+0.1214 inches