NSN: 5925-01-262-6151
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency In Hertz
400.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac fourth location and 1000.0 dc fourth location
-
Auxiliary Switch Function And Quantity
1 alarm
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac fourth location and 65.0 dc fourth location
-
Manual Actuator Type And Quantity
4 toggle
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
-
Switch Voltage Rating And Type In Volts
240.0 ac and 50.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic
-
Boss Height
0.130 inches nominal
-
Pole Quantity
4
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
-
Test Data Document
18323-7489a63 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Mounting Surface To Terminal End Distance
2.032 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
8 threaded hole
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Internal Trip Release Configuration
series trip first location
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac second location
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Switch Contact Arrangement
single pole, double throw
-
Internal Trip Release Configuration
series trip second location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
-
Nominal Thread Size
0.138 inches
-
Internal Trip Release Configuration
series trip third location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct all locations and 1.900 maximum at 200 pct all locations
-
Inclosure Protection Type For Which Designed
shock resistant and moisture resistant and vibration resistant
-
Terminal Type And Quantity
10 tab w/screw
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
-
Internal Trip Release Configuration
relay trip fourth location
-
Switch Terminal Type
tab, solder lug
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Body Width
3.015 inches maximum
-
Switch Current Rating And Type In Amps
5.0 ac and 5.0 dc
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac fourth location and 15.0 amperes dc fourth location