NSN: 5925-01-265-7708

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Storage Type

    general purpose warehouse

  • Body Height

    2.312 inches nominal

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Mounting Facility Type And Quantity

    3 terminal

  • Body Style

    multipole-multiple actuator type

  • ~1

    data on certain environmental and performance re

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Center To Center Distance Between Terminals Parallel To Width

    1.000 inches nominal

  • Boss Height

    0.250 inches nominal

  • Body Width

    3.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Body Length

    3.094 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Specification/Standard Data

    81348-w-c-375/15 government specification

  • Trip Delay Time In Seconds Per Rated Continuous Current

    120.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Terminal Type And Quantity

    3 compression and 3 quick disconnect, male

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...