Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    120.0 amperes ac all locations and 120.0 amperes dc all locations

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Body Length

    2.203 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Terminal Type And Quantity

    4 screw

  • Mounting Surface To Terminal End Distance

    2.031 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    600.0 ac all locations and 600.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.437 inches nominal

  • Arc Quenching Method

    air

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.781 inches nominal

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    595.000 nominal at 200 pct all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.164 inches

  • Body Width

    1.546 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations and 30.0 dc all locations

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...