NSN: 5925-01-270-7837

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    4

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Width

    4.104 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Arc Quenching Method

    air

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Terminal Type And Quantity

    8 threaded stud

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Length

    3.547 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    5.800 inches nominal

  • Mounting Facility Type And Quantity

    8 threaded hole and 8 slot

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Boss Height

    0.219 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Mounting Slot Width

    0.164 inches nominal

  • Manual Actuator Type And Quantity

    4 toggle

  • Case Material

    plastic

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...