NSN: 5925-01-271-2141

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Maximum Continuous Load Current Rating Per Pole

    225.0 amperes ac all locations and 225.0 amperes dc all locations

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +1000.0/+2250.0 ac all locations and +1000.0/+2250.0 dc all locations

  • Body Width

    4.130 inches nominal

  • Body Length

    10.125 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Circuit Protection Type

    overcurrent second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.750 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.380 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.380 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Circuit Protection Type

    undervoltage third location

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Center To Center Distance Between Terminals Parallel To Length

    8.380 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    22000.0 ac all locations and 10000.0 dc all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Body Height

    3.810 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole one

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...