NSN: 5925-01-274-6986

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations and 250.0 dc all locations

  • Terminal Type And Quantity

    2 clip and 2 compression

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations and 10000.0 dc all locations

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations and 15.0 amperes dc all locations

  • Body Length

    6.000 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Boss Height

    0.125 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    3.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Body Style

    multipole-single actuator type

  • Actuator Position Designation

    at pole two

  • Body Height

    3.000 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct all locations and 125.000 maximum at 200 pct all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.125 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...