NSN: 5925-01-274-9086

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Height

    3.156 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Body Width

    4.469 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.125 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Features Provided

    walking beam interlock

  • Case Material

    plastic

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Boss Height

    0.125 inches nominal

  • Body Length

    6.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 minimum at 200 pct all locations and 90.000 maximum at 200 pct all locations

  • Unthreaded Mounting Hole Diameter

    0.172 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...