NSN: 5925-01-277-3200
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations and 100.0 amperes dc all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.735 inches minimum and 2.765 inches maximum
-
Thread Quantity Per Inch
32
-
Special Features
back mount only
-
Center To Center Distance Between Terminals Parallel To Length
3.535 inches minimum and 3.565 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Mounting Facility Type And Quantity
6 threaded hole
-
Center To Center Distance Between Terminals Parallel To Width
1.011 inches minimum and 1.041 inches maximum
-
Nominal Thread Size
0.138 inches
-
Body Length
5.110 inches minimum and 5.130 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct all locations and 120.000 maximum at 200 pct all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 125.0 dc all locations
-
Mounting Surface To Terminal End Distance
2.535 inches minimum and 3.565 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Body Width
3.093 inches minimum and 3.108 inches maximum
-
Unpackaged Unit Weight
2.000 pounds
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.011 inches minimum and 1.041 inches maximum
-
Features Provided
high inrush protection
-
Boss Height
0.205 inches minimum and 0.235 inches maximum
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations and 5000.0 dc all locations