NSN: 5925-01-281-7511

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.130 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.250 inches nominal

  • Body Width

    4.120 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations and 10000.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    2.625 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    2.750 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    251.0 amperes ac all locations and 251.0 amperes dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    60.0 all locations or 400.0 all locations

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 compression

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Special Features

    includes single front connected mounting base

  • Body Style

    multipole-single actuator type

  • Body Height

    3.880 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Body Length

    6.500 inches nominal

  • Actuator Position Designation

    at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Trip Release Characteristic

    instantaneous all locations

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    dustproof

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...