NSN: 5925-01-294-4658

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    1a single pole type

  • Bushing Length

    0.250 inches nominal

  • Body Width

    0.562 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Surface To Terminal End Distance

    1.600 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Trip Release Method

    thermal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Switch Terminal Type

    turret

  • Terminal Type And Quantity

    2 tab w/screw

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    instantaneous single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.438 inches

  • Switch Location And Position Designation

    external at pole one

  • Inclosure Protection Type For Which Designed

    dustproof

  • Frequency In Hertz

    400.0 single location

  • Thread Series Designator

    un

  • Body Length

    0.750 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    0.740 inches nominal

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...