NSN: 5925-01-294-4659
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
1a single pole type
-
Bushing Length
0.760 inches minimum and 0.775 inches maximum
-
Body Length
0.719 inches minimum and 0.781 inches maximum
-
Body Width
0.880 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.469 inches minimum and 0.531 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Special Handling Feature
magnetic
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
-
Trip Release Method
thermal single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.438 inches
-
Switch Location And Position Designation
external at pole one
-
Inclosure Protection Type For Which Designed
dustproof
-
Terminal Type And Quantity
2 tab w/screw
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.630 inches maximum
-
Pole Quantity
1
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Characteristic
instantaneous single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at pole one
-
Auxiliary Switch Function And Quantity
1 alarm
-
Trip Release Ambient Temp Rating
40.0 deg celsius nominal single location
-
Switch Terminal Type
turret
-
Frequency In Hertz
400.0 single location
-
Thread Series Designator
un