Technical Characteristics

  • Body Style

    1a single pole type

  • Bushing Length

    0.760 inches minimum and 0.775 inches maximum

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Body Width

    0.880 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.438 inches

  • Switch Location And Position Designation

    external at pole one

  • Inclosure Protection Type For Which Designed

    dustproof

  • Terminal Type And Quantity

    2 tab w/screw

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.630 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    instantaneous single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Switch Terminal Type

    turret

  • Frequency In Hertz

    400.0 single location

  • Thread Series Designator

    un

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.