NSN: 5925-01-296-2883

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 screw

  • Inclosure Protection Type For Which Designed

    dustproof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and 55.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Trip Release Method

    thermal single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac and 20.0 amperes dc single location

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.188 inches nominal

  • Overall Width

    0.750 inches maximum

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    1

  • Boss Height

    0.250 inches nominal

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Overall Length

    2.189 inches maximum

  • Body Style

    5a single pole type

  • Thread Series Designator

    unc

  • Frequency In Hertz

    400.0

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Nominal Thread Size

    0.138 inches

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push-pull

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Trip Release Characteristic

    time delay single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac and 6000.0 dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac and 30.0 dc single location

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...