NSN: 5925-01-297-9389

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.645 inches minimum and 1.675 inches maximum

  • Boss Height

    0.115 inches minimum and 0.145 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt water resistant and shock resistant and vibration resistant

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct single location and 10.000 maximum at 200 pct

  • Special Features

    actuator black without markings

  • Unpackaged Unit Weight

    2.200 pounds

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...