NSN: 5925-01-299-4468

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Trip Release Method

    magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Boss Height

    0.140 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Body Width

    1.500 inches nominal

  • Body Length

    2.500 inches nominal

  • Body Style

    8c multipole-multiple actuator type

  • Terminal Type And Quantity

    4 threaded stud

  • Unpackaged Unit Weight

    7.400 ounces

  • Frequency In Hertz

    50.0 all locations or 60.0

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct

  • External Actuator Linkage Arrangement

    one and two linked

  • Manual Actuator Type And Quantity

    2 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Trip Release Characteristic

    time delay all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Case Material

    plastic

  • Thread Pitch Diameters

    0.1177 to 0.1214 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...