NSN: 5925-01-300-7711
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.300 minimum at 200 pct all locations and 8.000 maximum at 200 pct all locations
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
4.0 dc minimum second location and 12.0 dc maximum second location
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Nonturn Device Length
0.161 inches minimum and 0.990 inches maximum
-
Trip Release Method
magnetic all locations
-
Nonturn Device Radius
0.594 inches minimum and 0.656 inches maximum
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Internal Trip Release Configuration
series trip first location
-
Internal Trip Release Configuration
series/relay trip second location
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Frequency In Hertz
462.0 all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
between pole one and two
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Terminal Type And Quantity
4 wire hook and 2 tab, solder lug
-
Body Length
1.562 inches maximum
-
Thread Series Designator
unef
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations
-
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac all locations
-
Body Width
1.281 inches maximum
-
Nonturn Device Diameter
0.219 inches minimum and 0.281 inches maximum
-
Bushing Length
0.380 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
-
Fragility Factor
moderately rugged
-
Trip Release Duty Cycle
intermittent all locations
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum