Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Height

    4.062 inches nominal

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    125.0 amperes ac all locations and 125.0 amperes dc all locations

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations and 22000.0 dc all locations

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Pole Quantity

    2

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +625.0/+1250.0 ac all locations and +625.0/+1250.0 dc all locations

  • Features Provided

    adjustable trip release

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Body Length

    10.000 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.250 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    8.094 inches nominal

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...