NSN: 5925-01-304-0505

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    4 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac fourth location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Trip Release Method

    magnetic-hydraulic fourth location

  • Trip Release Method

    magnetic-hydraulic second location

  • Trip Release Method

    magnetic-hydraulic third location

  • Trip Release Characteristic

    time delay fourth location

  • Trip Release Characteristic

    time delay second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 fourth location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Auxiliary Switch Function And Quantity

    1 control

  • Internal Trip Release Configuration

    series trip fourth location

  • Internal Trip Release Configuration

    series trip second location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct fourth location and 20.000 maximum at 200 pct

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct second location and 20.000 maximum at 200 pct

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct third location and 20.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    dustproof and fungus resistant

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Internal Trip Release Configuration

    series trip third location

  • Switch Terminal Type

    threaded stud

  • Special Features

    first pole is a switch only

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    3.015 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.406 inches minimum and 2.656 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    1.930 inches minimum and 1.950 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.140 inches minimum and 0.160 inches maximum

  • Pole Quantity

    4

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac fourth location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac second location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac third location

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac fourth location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Circuit Protection Type

    overcurrent fourth location

  • Circuit Protection Type

    overcurrent second location

  • Circuit Protection Type

    overcurrent third location

  • Trip Release Characteristic

    time delay third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 third location

  • Reset Method

    manual

  • Frequency In Hertz

    60.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...