NSN: 5925-01-305-1415
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Boss Height
0.115 inches minimum and 0.145 inches maximum
-
Storage Type
general purpose warehouse
-
Inclosure Protection Type For Which Designed
salt spray proof and moisture resistant and shock resistant and vibration resistant
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Surface To Terminal End Distance
2.032 inches maximum
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.645 inches minimum and 1.675 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Special Features
toggle black without markings
-
Mounting Facility Type And Quantity
6 threaded hole
-
Body Width
2.265 inches maximum
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Switch Location And Position Designation
external at pole one
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2100.0 ac all locations
-
Nominal Thread Size
3.0 millimeters
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Thread Pitch In Millimeters
0.50
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct all locations and 1.900 maximum at 200 pct all locations
-
Terminal Type And Quantity
6 screw
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
iso m
-
Auxiliary Switch Function And Quantity
1 alarm
-
Manual Actuator Type And Quantity
3 toggle
-
Unpackaged Unit Weight
9.000 ounces
-
Switch Terminal Type
solder stud
-
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac all locations
-
Case Material
plastic