NSN: 5925-01-311-5010

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Center To Center Distance Between Terminals Parallel To Width

    0.600 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches maximum

  • Boss Height

    0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    2.755 inches maximum

  • Mounting Facility Type And Quantity

    6 unthreaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Ultimate Trip Time Per Pole In Seconds

    0.600 nominal all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 push-pull

  • Internal Trip Release Configuration

    series/relay trip all locations

  • Trip Release Duty Cycle

    continuous all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Body Length

    2.500 inches maximum

  • Body Width

    2.280 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.156 inches nominal

  • Iii End Item Identification

    f015 acft

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Circuit Protection Type

    overvoltage all locations

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    250.0 ac nominal all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    reset

  • Frequency In Hertz

    400.0 all locations

  • Manufacturers Code

    55974

  • Mfr Source Controlling Reference

    2131644-8

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.