NSN: 5925-01-315-3806

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Style

    rectangular dimensional envelope

  • Overall Length

    9.120 inches nominal

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Overall Width

    8.240 inches minimum and 8.250 inches maximum

  • Switch Terminal Type

    wire lead

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Auxiliary Switch Function And Quantity

    4 alarm

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Overall Height

    5.380 inches maximum

  • Switch Current Rating And Type In Amps

    6.0 ac and 0.250 dc

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    22000.0 ac all locations and 10000.0 dc all locations

  • Terminal Type And Quantity

    6 compression

  • Switch Location And Position Designation

    external at pole three

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Special Features

    48 vdc shunt trip with wire leads installed on right side of circuit breaker; 120 vac motor operator mounted on front of circuit breaker,5.750 inch lg,3.230 inch w,10.120 inch h

  • Unthreaded Mounting Hole Diameter

    0.310 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Maximum Continuous Load Current Rating Per Pole

    400.0 amperes ac all locations and 400.0 amperes dc all locations

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +1200.0/+4000.0 ac all locations and +1200.0/+4000.0 dc all locations

  • Switch Voltage Rating And Type In Volts

    240.0 ac and 250.0 dc

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...