Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Actuator Position Designation
at pole two
-
Switch Contact Arrangement
single pole, double throw
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Nonturn Device Diameter
0.151 inches minimum and 0.161 inches maximum
-
Thread Pitch Diameters
+0.4752/+0.4787 inches
-
Body Style
multipole-single actuator type
-
Unpackaged Unit Weight
6.000 ounces
-
Mounting Surface To Terminal End Distance
2.200 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Bushing Length
0.625 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Switch Current Rating And Type In Amps
10.0 ac and 5.0 dc
-
Arc Quenching Method
magnetic blowout
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Thread Series Designator
un
-
Switch Terminal Type
quick disconnect, male
-
~1
and 7.000 minimum at 125 pct all locations an
-
Trip Delay Time In Seconds Per Rated Continuous Current
90.000 maximum at 125 pct all locations and 1.000 minimum at 200 pct all locations and 0.080 minimum at 600 pct all locations and 0.030 minimum at 800 pct all locations and 0.700 maximum at 800 pct all locations and 0.200 minimum at 400 pct all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations
-
Terminal Type And Quantity
4 quick disconnect, male
-
Nonturn Device Radius
0.656 inches nominal
-
Body Width
1.500 inches nominal
-
Inclosure Protection Type For Which Designed
hermetically sealed and shock resistant and vibration resistant
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic
-
Nonturn Device Length
0.130 inches nominal