NSN: 5925-01-317-9967
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Actuator Position Designation
at pole two
-
Switch Contact Arrangement
single pole, double throw
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Nonturn Device Diameter
0.151 inches minimum and 0.161 inches maximum
-
Thread Pitch Diameters
+0.4752/+0.4787 inches
-
Body Style
multipole-single actuator type
-
Unpackaged Unit Weight
6.000 ounces
-
~1
and 12.000 maximum at 200 pct all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 maximum at 400 pct all locations and 0.030 minimum at 800 pct all locations and 40.000 maximum at 150 pct all locations and 3.000 minimum at 150 pct all locations and 0.080 minimum at 600 pct all locations and 90.000 maximum at 125 pct all locations
-
Nonturn Device Length
0.130 inches nominal
-
Case Material
plastic
-
Switch Location And Position Designation
internal at pole one
-
Body Width
1.500 inches nominal
-
Nonturn Device Radius
0.656 inches nominal
-
Terminal Type And Quantity
4 quick disconnect, male
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations
-
Switch Terminal Type
quick disconnect, male
-
Thread Series Designator
un
-
Auxiliary Switch Function And Quantity
1 alarm
-
Inclosure Protection Type For Which Designed
shock resistant and hermetically sealed and vibration resistant
-
Maximum Continuous Load Current Rating Per Pole
1.7 amperes ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Switch Current Rating And Type In Amps
10.0 ac and 5.0 dc
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Bushing Length
0.625 inches nominal
-
Manual Actuator Type And Quantity
1 toggle
-
Mounting Surface To Terminal End Distance
2.200 inches maximum