  • Body Style

    10b multipole-single actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches maximum

  • Boss Height

    0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    3.055 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Duty Cycle

    continuous all locations

  • Frequency In Hertz

    400.0 all locations

  • Manufacturers Code

    55974

  • Mfr Source Controlling Reference

    2131644-9

  • Terminal Type And Quantity

    6 screw

  • Body Length

    2.500 inches maximum

  • Body Width

    2.280 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches maximum

  • Iii End Item Identification

    f015 acft

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded stud

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    125.0 ac nominal all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series/relay trip all locations

  • Nominal Thread Size

    0.625 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 maximum at 200 pct all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...