NSN: 5925-01-321-3603
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
2 clip
-
Features Provided
high inrush protection
-
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac and 7.0 amperes dc .
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac and 1000.0 dc .
-
Circuit Protection Type
overcurrent .
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 tab, solder lug
-
Body Height
1.360 inches nominal
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Pole Quantity
1
-
Arc Quenching Method
magnetic blowout
-
Body Width
0.980 inches nominal
-
Boss Height
0.320 inches nominal
-
Storage Type
general purpose warehouse
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 32.0 dc .
-
Trip Release Method
magnetic-hydraulic .
-
Trip Release Characteristic
time delay .
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip .
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 200 pct and 41.000 maximum at 200 pct .
-
Inclosure Protection Type For Which Designed
dustproof and fungus proof
-
Frequency In Hertz
60.0
-
Body Style
caaql 10a
-
Body Length
2.060 inches nominal