ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    3.537 inches minimum and 3.557 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    3.475 inches minimum and 3.495 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    120.0 amperes dc second location

  • Maximum Continuous Load Current Rating Per Pole

    150.0 milliamperes dc first location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc second location

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    4.740 inches minimum and 4.760 inches maximum

  • Body Width

    2.072 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.016 inches minimum and 1.036 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Pole Quantity

    2

  • Storage Type

    general purpose warehouse

  • Features Provided

    high inrush protection

  • Operating Voltage Type And Rating Per Pole In Volts

    18.0 dc first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Trip Release Characteristic

    instantaneous first location

  • Trip Release Characteristic

    time delay second location

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one and two linked

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 13.000 maximum at 200 pct second location

  • Thread Series Designator

    unc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    vibrationproof and moisture resistant and shock resistant and salt spray proof

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.