NSN: 5925-01-323-5784

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Body Length

    2.530 inches maximum

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac first location

  • Center To Center Distance Between Terminals Parallel To Length

    1.924 inches minimum and 1.952 inches maximum

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    2.280 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac second location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct second location and 0.800 maximum at 200 pct second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Manual Actuator Type And Quantity

    3 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct third location and 0.800 maximum at 200 pct third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct first location and 80.000 maximum at 200 pct first location

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac third location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Thread Quantity Per Inch

    32

  • Boss Height

    0.155 inches maximum

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Mounting Surface To Terminal End Distance

    2.415 inches minimum and 2.535 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...