NSN: 5925-01-325-4404
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Nonturn Device Width
0.110 inches nominal
-
Nonturn Device Location
at 12 oclock
-
Center To Center Distance Between Terminals Parallel To Length
0.930 inches nominal
-
Circuit Protection Type
overcurrent single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
Body Width
0.710 inches nominal
-
Inclosure Protection Type For Which Designed
corrosion resistant and dustproof and vibrationproof and fungus proof and humidity proof
-
Pole Quantity
1
-
Body Length
1.220 inches nominal
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Nonturn Device Length
0.060 inches nominal
-
Bushing Length
0.260 inches nominal
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 6000.0 dc single location
-
Mounting Surface To Terminal End Distance
1.730 inches maximum
-
Body Style
single pole type
-
Trip Release Method
magnetic-hydraulic single location
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location
-
Frequency In Hertz
60.0 single location
-
Terminal Type And Quantity
2 tab w/screw
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.480 minimum at 200 pct single location and 10.500 maximum at 200 pct single location
-
Case Material
plastic