NSN: 5925-01-326-4289

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    300.0 amperes ac all locations

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +1500.0/+3000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Center To Center Distance Between Terminals Parallel To Width

    1.880 inches nominal

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

  • Switch Current Rating And Type In Amps

    15.0 ac

  • Fragility Factor

    moderately rugged

  • Body Length

    17.130 inches nominal

  • Trip Release Characteristic

    instantaneous all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Nominal Thread Size

    0.500 inches

  • Storage Type

    general purpose warehouse

  • Switch Location And Position Designation

    internal at pole two

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Body Width

    8.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.250 inches nominal

  • Inclosure Protection Type For Which Designed

    moisture proof and fungus proof

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Center To Center Distance Between Terminals Parallel To Length

    14.750 inches nominal

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    150000.0 ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Thread Quantity Per Inch

    13

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Height

    3.690 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.220 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...