NSN: 5925-01-327-5458
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Manual Actuator Type And Quantity
1 toggle
-
Nominal Thread Size
0.138 inches
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Boss Height
0.140 inches nominal
-
Inclosure Protection Type For Which Designed
moisture resistant and shockproof and vibrationproof and corrosion resistant and fungus resistant
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 minimum at 200 pct all locations and 1.800 maximum at 200 pct all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac third location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Mounting Surface To Terminal End Distance
2.000 inches maximum
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Actuator Position Designation
at pole two
-
Mounting Facility Type And Quantity
6 threaded hole
-
Body Style
multipole-single actuator type
-
Body Width
2.265 inches maximum
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Thread Quantity Per Inch
32
-
Unpackaged Unit Weight
11.100 ounces
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac second location
-
Body Length
2.490 inches nominal
-
Terminal Type And Quantity
6 threaded stud