NSN: 5925-01-327-7811
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Case Material
metal
-
Mounting Surface To Terminal End Distance
1.981 inches nominal
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
2 threaded stud
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
150.0 amperes ac single location
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
magnetic-hydraulic single location
-
Trip Release Characteristic
instantaneous single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Nominal Thread Size
0.625 inches
-
Thread Series Designator
unc
-
Body Style
12a single pole type
-
Body Length
2.500 inches nominal
-
Body Width
0.760 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
End Item Identification
peace shield
-
Boss Height
0.140 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac single location
-
Reset Method
manual
-
Internal Trip Release Configuration
series trip single location
-
Frequency In Hertz
50.0 single location or 60.0
-
Terminal Type And Quantity
2 bus bar