Technical Characteristics

  • Pole Quantity

    3

  • Boss Height

    0.250 inches nominal

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    8.094 inches nominal

  • Case Material

    plastic

  • Body Length

    10.000 inches nominal

  • Body Style

    11b multipole-single actuator type

  • Terminal Type And Quantity

    6 compression

  • Thread Series Designator

    unc

  • Nominal Thread Size

    0.250 inches

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc

  • Features Provided

    adjustable trip release

  • Special Handling Feature

    magnetic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.704 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Body Height

    4.062 inches nominal

  • Body Width

    4.125 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Adjustable Trip Setting Current Range Per Pole In Amps

    160.0 to 200.0 ac all locations

  • Actuator Position Designation

    at pole two

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    18000.0 ac all locations and 10000.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    200.0 amperes ac all locations and 200.0 amperes dc

  • Thread Quantity Per Inch

    20

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Arc Quenching Method

    magnetic blowout

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...