NSN: 5925-01-330-9212
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
-
Pole Quantity
2
-
Bushing Length
0.610 inches minimum and 0.640 inches maximum
-
Internal Trip Release Configuration
series trip w/remote trip feature second location
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Nonturn Device Location
at 12 oclock
-
Thread Quantity Per Inch
32
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
115.0 ac nominal second location
-
Internal Trip Release Configuration
series trip first location
-
Actuator Position Designation
at pole two
-
Body Width
1.485 inches minimum and 1.515 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations and 150.000 maximum at 200 pct all locations
-
Thread Pitch Diameters
+0.4752/+0.4787 inches
-
Body Style
multipole-single actuator type
-
Terminal Type And Quantity
5 tab w/screw
-
Unpackaged Unit Weight
6.000 ounces
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Case Material
metal
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Operating Voltage Type And Rating Per Pole In Volts
220.0 ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Mounting Surface To Terminal End Distance
2.232 inches maximum
-
Inclosure Protection Type For Which Designed
salt spray proof and shock resistant and moisture resistant and corrosion resistant and vibration resistant
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Nonturn Device Radius
0.641 inches minimum and 0.671 inches maximum
-
Thread Series Designator
un
-
Trip Release Duty Cycle
continuous second location
-
Nonturn Device Length
0.115 inches minimum and 0.145 inches maximum