NSN: 5925-01-332-3264

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Body Width

    4.126 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Body Length

    6.023 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations and 250.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.688 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.688 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations and 100.0 amperes dc all locations

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Style

    multipole-single actuator type

  • Arc Quenching Method

    deion

  • Mounting Surface To Terminal End Distance

    3.375 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.164 inches

  • Boss Height

    0.125 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    2.250 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations and 10000.0 dc all locations

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.