NSN: 5925-01-332-3265

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Style

    multipole-single actuator type

  • Arc Quenching Method

    deion

  • Manual Actuator Type And Quantity

    1 toggle

  • Mounting Surface To Terminal End Distance

    3.375 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.164 inches

  • Boss Height

    0.125 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    2.250 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.688 inches nominal

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.688 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Body Width

    4.126 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac all locations

  • Body Length

    6.023 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...