NSN: 5925-01-332-9929

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct first location and 0.950 maximum at 200 pct first location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct second location and 0.950 maximum at 200 pct second location

  • Trip Release Characteristic

    instantaneous third location

  • Terminal Type And Quantity

    6 wire hook

  • Body Width

    1.281 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc second location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc first location

  • Thread Series Designator

    unef

  • Nonturn Device Radius

    0.581 inches minimum and 0.701 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.927 inches minimum and 0.947 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Body Length

    1.562 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Body Style

    multipole-single actuator type

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Actuator Position Designation

    at pole two

  • Trip Release Characteristic

    time delay first location

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes dc third location

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Inclosure Protection Type For Which Designed

    shockproof and moisture resistant and vibration resistant and salt spray proof

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.