NSN: 5925-01-339-6539

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Body Width

    0.750 inches nominal

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Special Features

    actuator white with black markings

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Arc Quenching Method

    magnetic blowout

  • Unpackaged Unit Weight

    2.200 ounces

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.