NSN: 5925-01-346-7825

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    relay trip fourth location

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac third location

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Internal Trip Release Configuration

    series trip second location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac first location

  • Body Width

    3.000 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac fourth location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay second location

  • Internal Trip Release Configuration

    series trip third location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac second location

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Characteristic

    time delay third location

  • Body Length

    2.500 inches nominal

  • Boss Height

    0.140 inches nominal

  • Trip Release Characteristic

    instantaneous fourth location

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.936 inches nominal

  • Manual Actuator Type And Quantity

    4 toggle

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Pole Quantity

    4

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Terminal Type And Quantity

    10 threaded stud

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct second location and 3.000 minimum at 200 pct third location and 3.000 minimum at 200 pct first location and 20.000 maximum at 200 pct third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct second location

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Internal Trip Release Configuration

    series trip first location

  • Trip Release Characteristic

    time delay first location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...