NSN: 5925-01-351-5542
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.375 inches nominal
-
Nominal Thread Size
0.375 inches
-
Inclosure Protection Type For Which Designed
general purpose and moisture resistant
-
Circuit Protection Type
overcurrent single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct single location and 70.000 maximum at 200 pct single location
-
Pole Quantity
1
-
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
50.0 single location or 60.0 single location
-
Body Style
single pole type
-
Trip Release Method
magnetic-hydraulic single location
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Thread Series Designator
unef
-
Mounting Surface To Terminal End Distance
2.125 inches nominal
-
Unpackaged Unit Weight
2.500 ounces
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 65.0 dc single location
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Thread Quantity Per Inch
52
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 1000.0 dc single location
-
Storage Type
general purpose warehouse
-
Body Width
0.750 inches nominal
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Terminal Type And Quantity
2 screw