NSN: 5925-01-357-5559

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Storage Type

    general purpose warehouse

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Bushing Length

    0.250 inches nominal

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Precious Material

    silver

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.376 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 200 pct all locations and 3.300 maximum at 200 pct all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Body Height

    1.875 inches maximum

  • Body Style

    multipole-single actuator type

  • Body Width

    1.300 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.688 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Precious Material And Location

    contact surfaces silver

  • Inclosure Protection Type For Which Designed

    general purpose

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Body Length

    2.063 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded stud

  • Nominal Thread Size

    0.469 inches

  • Case Material

    ceramic

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...