NSN: 5925-01-358-2662

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Inclosure Protection Type For Which Designed

    corrosion resistant and explosion resistant and humidity resistant

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    0.703 inches nominal

  • Mounting Surface To Terminal End Distance

    1.852 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    60.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.593 inches maximum

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Body Length

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.085 inches minimum and 0.100 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...