NSN: 5925-01-360-1453

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • External Actuator Linkage Arrangement

    one and two linked and two and three linked

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    110.0 all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    4.125 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.063 inches nominal

  • Manual Actuator Type And Quantity

    1 push button and 1 toggle

  • Trip Release Method

    thermal-magnetic all locations

  • Body Width

    5.500 inches nominal

  • Unpackaged Unit Weight

    4.500 pounds

  • Body Height

    3.500 inches nominal

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Style

    multipole-single actuator type

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Nominal Thread Size

    0.164 inches

  • Boss Height

    0.125 inches nominal

  • Terminal Type And Quantity

    6 screw

  • Trip Release Duty Cycle

    continuous all locations

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations

  • Body Length

    6.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Actuator Position Designation

    between pole one and two and between pole two and three

  • Center To Center Distance Between Terminals Parallel To Length

    5.063 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...