NSN: 5925-01-360-8127
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac second location
-
Body Width
1.937 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Body Length
1.562 inches maximum
-
Terminal Type And Quantity
6 screw
-
Frequency In Hertz
50.0 first location or 50.0 second location or 60.0 second location
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac second location
-
Thread Series Designator
unef
-
Unpackaged Unit Weight
5.400 ounces
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc third location
-
Features Provided
high inrush protection
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 maximum at 200 pct third location
-
Mounting Surface To Terminal End Distance
1.950 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
1.5 amperes dc third location
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.950 maximum at 200 pct second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
-
Nominal Thread Size
0.375 inches
-
Frequency In Hertz
60.0 first location
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac first location
-
Actuator Position Designation
at pole two
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac first location
-
Body Style
multipole-single actuator type
-
Inclosure Protection Type For Which Designed
hermetically sealed and shockproof and vibrationproof
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct first location and 0.055 minimum at 200 pct second location and 0.060 minimum at 200 pct third location and 0.950 maximum at 200 pct first location
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle